P2RF-0x-S, PYF-xx-S Datasheet by Omron Automation and Safety

View All Related Products | Download PDF Datasheet
CSM_PYF__S/P2RF-__-S_DS_E_2_5
1
Screwless Clamp Terminal Sockets
PYF
@@
S/P2RF-
@@
-S
New Screwless Terminal Sockets Added
for MY and G2R Relays.
Simplified wiring without tightening screws.
Two wires can be independently wired for each terminal.
Coil terminals and contact terminals are completely separated
in an organized wiring layout.
Release Levers and Labels are available (sold separately).
Features
Ordering Information
Sockets
Options (Order Separately)
Note: Pieces per Package
Labels: 100
Short Bars: 50
Applicable model (typical example) Socket
Model
MY2 PYF08S
MY4 PYF14S
G2R-1-S P2RF-05-S
G2R-2-S P2RF-08-S
Applicable Socket Release Bar Labels Short Bars with Red Insulation Short Bars with Blue Insulation
Model Model Model Model
PYF08S PYCM-08S
R99-11
PYDM-08SR PYDM-08SB
PYF14S PYCM-14S PYDM-14SR PYDM-14SB
P2RF-05-S P2CM-S P2RM-SR P2RM-SB
P2RF-08-S
Complete Wiring in Three StepsStructured for Easy Wiring
Insert
a screwdriver.
Screwdriver
inserted.
Insert the wire.
Remove screwdriver
to complete wiring.
• A spring holds the wire in place to reduce wiring work by 30%
(according to OMRON comparison) and eliminates the need to
manage torque.
• DIN terminal numbers also indicated.
Contact terminal
(common)
Coil terminals
Release Lever
(sold separately)
Label
(sold separately)
Contact terminal
(NO)
Contact terminal
(NC)
I
PYF@@S/P2RF-@@-S
2
Ratings/Characteristics
Characteristics
Sockets
PYF@@S
*The continuous carry current of 10 A for the PYF08S is for an ambient temperature of 55°C.
At an ambient temperature of 70°C, the value is 7 A.
P2RF-@@-S
Socket Accessories
Short Bars
Ratings for Safety Standard Certification
PYF@@S
P2RF-@@-S
Item Model PYF08S PYF14S
Ambient operating temperature 55 to 70°C
Ambient operating humidity 5% to 85%
Continuous carry current* 10 A 5 A
Dielectric
strength
Between contact
terminals of same
polarity
2,000 VAC, 1 min 2,000 VAC, 1 min
Between contact
terminals of
different polarity
2,000 VAC, 1 min 2,000 VAC, 1 min
Between coil and
contact terminals 2,000 VAC, 1 min 2,000 VAC, 1 min
Insulation resistance 1,000 MΩ min.
Weight (approx.) 46 g 62 g
Item Model P2RF-05-S P2RF-08-S
Ambient operating temperature 40 to 70°C
Ambient operating humidity 5% to 85%
Continuous carry current 10 A 5 A
Dielectric
strength
Between contact
terminals of same
polarity
1,000 VAC, 1 min 1,000 VAC, 1 min
Between contact
terminals of
different polarity
--- 3,000 VAC, 1 min
Between coil and
contact terminals 4,000 VAC, 1 min 4,000 VAC, 1 min
Insulation resistance 1,000 MΩ min.
Weight (approx.) 36 g 40 g
Application Applicable sockets Model
Maximum carry current
Ambient operating
temperature
Ambient operating
humidity
For Coil terminals PYF08S PYDM-08S@10 A 40 to 70°C 5% to 85%
PYF14S PYDM-14S@10 A 40 to 70°C 5% to 85%
Standard File No.
VDE0627 (EN61984) Certificate No. 40015509
UL508 (UL1059) E87929 Vol.3
CSA C22.2 No.14 (CSA C22.2 No.158) LR31928
Standard File No.
VDE0627 (EN61984) Certificate No. 40002313
UL508 (UL1059) E87929 Vol.3
CSA C22.2 No.14 (CSA C22.2 No.158) LR31928
3
PYF@@S/P2RF-@@-S
Dimensions (Unit: mm)
Sockets
9
5
1
13
12
8
4
14
32.6
27.6
22.6
(5.3)
(3.4)
(5) 28.6
32.6
35.4
24.5
36.5 max.
38.2 max.
23.2 max.
85 max.
Terminal Arrangement/
Internal Connection Diagram
(Top View)
(41) (11)
(44)
(42)
(A2) (A1)
(
12
)
(14)
Note: Figures in parentheses indicate
DIN standard numbers.
PYF08S
5678
9101112
1234
1314
Terminal Arrangement/
Internal Connection Diagram
(Top View)
36.5 max.
(4.15)
(3.4)
85 max.
31 max. 22.6
27.6
32.6
24.55
35.4
28.6
32.6
(41) (31) (21) (11)
(44) (34) (24) (14)
(42) (32)
(A2) (A1)
(22) (12)
Note: Figures in parentheses indicate
DIN standard numbers.
PYF14S
PYF@@S/P2RF-@@-S
4
4
3
2
15
91.8 max.
Terminal Arrangement/
Internal Connection Diagram
(Top View)
32.6
28.5
22.6
27.6
32.6
35.3
24.5
18.0 max.
(2.4) (5.3)
(11)
(14)
(12)
(
A1
)(
A2
)
Note: Figures in parentheses indicate
DIN standard numbers.
P2RF-05-S
(3.4)
18.0 max.
22.6
27.6
32.6
28.6
32.6
24.5
35.3
91.8 max.
3
6
5
7
8
4
2
1
(5.3)
(2.4)
Terminal Arrangement/
Internal Connection Diagram
(Top View)
(A1) (A2)
(21) (11)
(24) (14)
(22) (12)
Note: Figures in parentheses indicate
DIN standard numbers.
P2RF-08-S
w
5
PYF@@S/P2RF-@@-S
Accessories (Order Separately)
Short Bars
Note: Use the Socket Bridges for relay coil bridge wiring.
Release Levers
Mounting Heights
Applicable
Sockets Model Length (mm) Insulation
color
PYF08S PYDM-08SR 19.7 Red
PYDM-08SB Blue
PYF14S PYDM-14SR 27.5 Red
PYDM-14SB Blue
P2RF-@@-S P2RM-SR 14.3 Red
P2RM-SB Blue
9
Guide: 1.2 dia.
Insulating coating
14
Length
16
54.4
32.7
29.6
52.5
28
PYCM-14S PYCM-08S
16.8
40.35
36
P2CM-S
MY
72.6 64
28.6
(3.4)
PYF08S PYF14S P2RF-@@-S
G2R Relay
(65)
P2RF-@@-S
Socket
57
64 *
(72) *
Figures of height in () is with G2R Relays with Latching Lervers.
Values indicated with asterisks are for when using a PFP-N Track.
The values increase by approximately 9 mm when using a PFP-N Track.
,r—fy .‘rl Qtflé": L—» (— W‘\\\\_‘ ‘ ‘1" O K “$3.5?“ I
6
PYF@@S/P2RF-@@-S
Safety Precautions
Do not move the screwdriver up, down, or from side to side or
rotate it while it is inserted in the hole. Doing so may damage
internal components in the Socket.
Do not insert more than one wire into the same hole. Doing so may
cause abnormal heating.
There are two internally connected wiring holes for each terminal.
Insert the screwdriver along the hole wall as shown below.
When you remove a Socket from a support rail, insert the end of a
screwdriver into the fixture and move the screwdriver as shown by
the arrow in the following figure.
When you use a Release Lever to remove a Relay from a P2RF-
@@-S Socket, insert a screwdriver at the location shown in the
following figure and move the Release Lever in the direction
indicated by the arrow to release the lock on the release lever.
Wiring Tools
Applicable Screwdriver
Use a flat-blade screwdriver with a tip that is 2.5 mm wide (3.0 mm
max.).
Applicable Screwdriver (Example)
VESSEL No.9900 () 2.5 × 75
Applicable Wires
You can use either solid wires or stranded wires. Applicable wire
size: 0.2 to 1.5 mm2 (AWG24 to AWG16)
Strip 8 to 9 mm of insulation from the ends of the wires.
If you insert stranded wires without ferrules, make sure that the
wires are twisted when you insert them.
If you use bare ferrules, always attach insulating sleeves.
If you insert a wire with a sheath outer diameter of 2.2 mm or less,
do not insert the wire far enough so that the sheath is engaged
inside the hole, as shown below.
Two wires with a sheath outer diameter of 3.2 mm or larger cannot
be inserted for the same terminal at the same time.
Use heat-shrinking tubes to indicate wire numbers.
Precautions for Safe Use
Screwdriver
Screwdriver
Fixture rail
Precautions for Correct Use
2.5 mm (3.0 mm max. )
Yo u cannot use a screwdriver with a thick shaft.
8 to 9 mm
\\\\\\\ :f/ I
PYF@@S/P2RF-@@-S
7
Wiring
(1) Insert a screwdriver into a screwdriver insertion hole on the
Socket.
(2) Press the screwdriver in until it reaches the stopper inside the
Socket. The spring at the back of the wire insertion hole will be
completely open in this condition. The screwdriver will be held in
place even if you remove your hand.
(3) With the screwdriver held in place, insert the wire or ferrule into
the wire insertion hole.
(4) Remove the screwdriver. The spring will hold the wire. This
concludes the connection procedure.
12 11 10 9
41 31 21 11
Wire insertion holes
Screwdriver insertion holes
A
A
Wire insertion hole
Screwdriver insertion hole
Screwdriver
Cross-section A-A
Spring
Wire
Terms and Conditions Agreement Read and understand thrs catalog. Warranties. See httg://www.omron.com/global/ Limrtalron on Liabrlity‘ Etc. Surtabrrig of Use. Programmable Products. Performance Data. Change in Specrticatron Errors and Omissions. n o ass 20155
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omrons analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omrons test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2018.5
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2018 All Right Reserved.

Products related to this Datasheet

RELAY SOCKET 8 POSITION DIN RAIL
CLIP AND RELEASE LEVER FOR P2RF
SOCKET BRIDGE DC FOR P2RF
SOCKET BRIDGE AC FOR P2RF
SOCKET BRIDGE 2-POS FOR MY RELAY
SOCKET BRIDGE 2-POS FOR MY RELAY
SOCKET BRIDGE 4-POS FOR MY RELAY
SOCKET BRIDGE 4-POS FOR MY RELAY