BFB0312HA-A116 Spec Datasheet by Delta Electronics

View All Related Products | Download PDF Datasheet
A ISELTlI
DEL-0776A4
SPECIFICATION FOR APPROVAL
===============================================
Customer Digikey
Description DC BLOWER
Part No. Rev.
Delta Model No. BFB0312HA-A116 Rev. 01
Sample Issue No.
Sample Issue Date. Sep 19, 2014
PLEASE SEND ONE COPY OF THIS SPECIFICATION
BACK AFTER YOU SIGNED APPROVAL FOR PRODUC-
TION PRE-ARRANGEMENT.
APPROVED BY : _____________________________
DATE : _____________________________
DELTA ELECTRONICS (THAILAND) PUBLIC COMPANY LIMITED.
111 MOO 9 WELLGROW INDUSTRIAL ESTATE
BANGNA-TRAD ROAD, TAMBON BANGWUA,
AMPHUR BANGPAKONG, CHACHOENGSAO 24180 THAILAND
TEL. +66-(0)-38522455, FAX. +66-(0)-38522477
DELTA ELECTRONICS (THAILAND) PCL. 111 M00 9, WELLGROW INDUSTRIAL ESTATE, TEL : +66—(0)38—522455 BANGNA—TRAD ROAD, BANGWUA, BANGPAKONG, FAX : +66—(0)38—522477 CHACHEONGSAO 24180 THAILAND. SPECIFICATION FOR APPROVAL ’5’K>11’5’5’K>11>11’K**********************¥* Customer: Digikey Customer P/N: Delta Model N Sample Rev: 1. SCOPE: THIS SPECIFICATION DEFINES THE ELECTRICAL AND MECHANICAL CHARACTERISTICS OF THE DC BRUSHLESS BLOWER. THE BLOWER MOTOR IS WITH ONE PHASE AND EIGHT POLES. 2. CHARACTERS: UNLESS SPECIFIED, ALL READINGS AND TESTS ARE BASED ON 25 DEG C, 65% RH. E 77777777777777777 ITEM 7"7""WWEESERIEHON 7777777777777 E RATED VOLTAGE 12 v00 E OPERATION VOLTAGE 7.0 — 13.2 vnc i E 0.00 (MAX. 0.09) A E E INPUT CURRENT E E SAFETY CURRENT 0N LABEL : 0.09A : E INPUT POWER 0.72 (MAX. 1.00) w E P PPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPP E E SPEED 7500 :(g; R.P.M. E E MAX. AIR FLOW 0.041 (MIN. 0.033) M3 / MIN. E E (AT ZERO STATIC PRESSURE) 1.45 (MIN. 1.17 ) CFM i MAX.AIR PRESSURE 7.24 (MIN. 4.63 ) mmHZO 1 (AT ZERO AIRFLOW) 0.205 (MIN. 0.102 ) inchHZO : (continued) page: 1 A00
PART NO: 10 MEG OHM MIN. AT 500 vnc 1 (BETWEEN FRAME AND (+) TERMINAL) 1 5 mA MAX. AT 500 VAC 50/60 Hz 1 ONE MINUTE, (BETWEEN FRAME AND 1 (+) TERMINAL) 1 LIFE EXPECTANCE (AT LABEL VOLTAGE) L10, 30,000 HOURS AT 40°C WITH 15 ~ 65 ZRH. COUNTERCLOCKWISE DIRECTION FROM FRONT VIEW OF AIR FLOW INLET UL 1571 AWG #23 BLACK WIRE NEGATIVE(-) RED WIRE POSITIVE(+) NOTES: 1. ALL READINGS ARE MEASURED AFTER STABLY WARMING UP THROUGH 10 MINUTES. 21 STANDARD AIR PROPERTY IS AIR AT (Td) 25°C TEMPERATURE, (RH) 65% RELATIVE HUMIDITY, AND (Pb) 760 mmHg BAROMETRIC PRESSURE. THE VALUES WRITTEN IN PARENS , ( ), ARE LIMITED SPECI 4. ACOUSTICAL NOISE MEASURING CONDITION: 9" BLOWER MICROPHONE <2: air="" flow="" —————————————————="" 1m="" noise="" is="" measured="" at="" rated="" voltage="" in="" free="" air="" in="" anechoic="" chamber="" with="" b="" 8:="" k="" sound="" level="" meter="" with="" microphone="" at="" a="" distance="" of="" one="" meter="" from="" the="" fan="" intaigi.="" page:="" 2="" a00="">
3. MECHANICAL: 3—1. DIMENSIONS —————————————————————————————————— SEE DIMENSIONS DRAWING 3—2. FRAME ~ 7* PLASTIC UL: 94v—0 3—3. IMPELLER ——————————————————————————————————————————— PLASTIC UL: 94V—0 3—4. EEARING SYSTEM rrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrr Two BALL BEARING 3—5. WEIGHT 777777777777777777777777777777777777777777777777777777 10 GRAMS 4. ENVIRONMENTAL: 4—1. OPERATING TEMPERATURE —lO T0 +7O DEGREE C 4—2. STORAGE TEMPERATURE 7777777777777777777777 —40 T0 +75 DEGREE c 4—3. OPERATING HUMIDITY —————————————————————————————————— 5 T0 90 7.. RH 4—4. STORAGE HUMIDITY 7777777777777777777777777777777777777 5 T0 95 % RH 5. PROTECTION: 5-1. LOCKED ROTOR PROTECTION PROTECTS MOTOR FROM FIRE IN 96 HOURS OF LOCKED ROTOR CONDITION AT THE RATED VOLTAGE. 5—2. POLARITY PROTECTION BE CAPABLE OF WITHSTANDING IF REVERSE CONNECTION FOR POSITIVE AND NEGATIVE LEADS. 6. RE OZONE DEPLETING SUBSTANCES: 6—1. N0 CONTAINING PBBs, PBEOS, CFCS, PEBES. PBDPES AND HCFCS. 7. PRODUCTION LOCATION 7-1. PRODUCTS WILL BE PRODUCED IN CHINA OR THAILAND . page: 3 A00
8. BASIC RELIABILITY REQUIREMENT: B-l. THERMAL LOW TEMPERATURE: -40°C CYCLING HIGH TEMPERATURE: +80°C SOAK TIME: 30 MINUTES TRANSITION TIME < 5="" minutes="" duty="" cycles:="" 5="" 0—2.="" humidity="" temperature:="" +25°c="" ~="" +65”c="" exposure="" humidity:="" 90-90%="" rh="" 6="" +65°c="" for="" 4="" hours/cycle="" power:="" non-operating="" test="" time:="" 168="" hours="" 8-3.="" vibration="" temperature:="" +25°c="" orientation:="" x,="" y,="" z="" power:="" non—operating="" vibration="" level:="" overall="" grms="3.2" frequency(hz)="" psn(c*2/hz)="" 10="" 0.040="" 20="" 0.100="" 40="" 0.100="" 800="" 0.002="" 1000="" 0.002="" test="" time:="" 2="" hours="" on="" each="" orientation="" 3-4.="" mechanical="" temperature:="" +20“c="" shock="" orientation:="" x,="" y,="" z="" power:="" non—operating="" acceleration:="" 20="" g="" min.="" pulse:="" 11="" ms="" half—sine="" wave="" number="" of="" shocks:="" 5="" shocks="" for="" each="" direction="" 3-5.="" life="" temperature:="" max="" ,="" operating="" temperature="" power:="" operating="" duration:="" 1000="" hours="" page:="" 4="" a00="">
PART NO: 9. P 8c Q CURVE: m. M ) 3/ m M W 5 0. 0 I5 4 1. 0. 0 I. m. 0. _ 0 \1 7 _ 7 _ 7 _ r r \\r M 7 7 _ . 7 7 7 0 _ 7 7 7 \5 _ 7 7 7 0. _ 7 7 7 1 4 4 7. ll. 0. _ 7 _ _ 7 7 7 0 _ 7 _ _ 7 7 7 _ 7 _ _ 7 7 7 _ 7 _ _ 7 7 7 _ 7 7 _ _ 7 7 7 0 I. 0 D 0. 0 0. 0. 0. 0. 0. 0. 0. 0 m 9 8 7 6 5 4 3 2 I AONEEEV _ _ _ _ 7 7 _ w m A m m. m M o 0. 0w 0 0 0 0 0 73575 mmammmmm E< :=""> INPUT VOLTAGE ------- RATED VOLTAGE TEMPERATURE 77 "7 ROOM TEMPERATURE AIR FLOW HUMIDITY --------- --- 65%RH ‘ TEST CONDITION: A00 page: 5
10. DIMENSION DRAWING: LABEL: A A Ix: aRusHu'ss A n: alusmzss m anusmm 0R “32%;;17: OR 1m 1 . 0- 0+0 5 30,0i05 ‘ ‘(7 (o 394% 020) (1.181i0020) 2—¢2.4i0.3 24,0i03; (27030.094i0012) (0.945i0101 2 |( (70299) (0.827) (0‘945i0.012) 30 ow 5 (1.181t0.020) 6.0 (0 236) 102 0:10 0 (4.000i0.394) Nr NOTES: UNIT: 1. CABLE WIRE: UL1571 AWG#28 (INCH) P1N1; BLACK WIRE 77777 (7) PM: RED w1RE 77777 (+) HOUSING: MOLEX 51021—0200 OR EQUIVALENT W~1PCEA TERMINAL: MOLEX 50058—8000 OR EQUIVALENT "fizpcg THIS PRODUCT 1s RoHS COMPLIANT 3‘9“!“ page: 6 A00
A hELTlI y- 10. 11. 12. 13. Application Notice Delta Will not guarantee the performance of the products ifthe application condition falls outside the parameters set forth in the specification. Awritten request should be submitted to Delta prior to approval if deviation from this specification is required. Please exercise caution when handling fans. Damage may be caused when pressure is applied to the impeller. if the fans are handled by the lead wires. or if the fan was hard-dropped to the production floor. Except as pertains to some special desig ' there is no guarantee that the products will be free from any such safety problems or failures as caused by the introduction of powder, droplets ofwater or encroachment of insect into the hub. The ahnve-mentioned conditions are representative of some unique examples and viewed as the first point of reference prior to all other information. It is very important to establish the correct polarity before connecting the fan to the power source. Positive (+) and Negative (7). Damage may be caused to the fans if connection is with reverse polarity. if there is no foolproof method to protect against such error specifically mentioned in this spec. Delta fans without special protection are not suitable where any corrosive fluids are introduced to their environment. Please ensure all fans are stored according to the storage temperature limits specified. Do not store fans in a high humidity environment. We highly recommend performance testing is conducted before shipping. if the fans have been stored over 6 months. Not all fans are provided with the Lock Rotor Protection feature. If you impair the rotation of the impeller for the fans that do not have this function. the performance of those fans will lead to failure. Please be cautious when mounting the fan. Incorrect mounting of fans may cause excess resonance, vibration and subsequent noise. It is important to consider safety when testing the fans. A suitable fan guard should be fitted to the fan to guard against any potential for personal injury. Except where specifically stated, all tests are carried out at room (ambient) temperature and relatise humidity conditions of 25"(‘. 65% RH. The test value is only for fan performance itself. Be certain to connect an “4.7M" or greater" capacitor to the fan externally when the application calls for using multiple fans in parallel, to avoid any unstable power. Doc No: FMBG-ES FormOOl Rev. 01 Date June 24. 2009

Products related to this Datasheet